Volatile Organic Compound (VOC) Sensor

Sensors

Volatile Organic Compound (VOC) Sensor

  • Vendor:Onset
Availability: In Stock
$5,472.00
Qty Price
Buy 1 $5,472.00 ea
Buy 10 $5,061.60 ea

Overview

Dependably measure volatile organic compounds with the TVOC sensor. With the deployment of a fixed continuous monitor, users can avoid dangers by monitoring areas in question. A variety of industries use the TVOC to minimize poisoning and explosions. 

Requires analog port selection during U30 system configuration and use of a S-FS-CVIA when using the H22-001 data logger. When using a U12 data logger or ZW series data loggers, this sensor requires a 4-20mA input cable (CABLE-4-20mA) and external power provided by an AC adapter (AC-SENS-1).

Highlighted Features

  • Intrinsically Safe for use in hazardous areas

In what environment does this sensor operate?

This sensor operates in an indoor environment.

What measurements does this sensor support?

The T-ION-TVOC sensor supports the following measurement: Volatile Organic Comp.

Measurement range:  selectable 0 - 10, 0 - 100, 0 - 1000 ppm (parts per million)
Accuracy:  (0-10 and 0-100 ppm)  +/- 2%; (100-1000 ppm) +/- 5%
Linearity:  (0 - 100 ppm)  > 98%
Input power, sensor:  5 - 28 VDC, 65 mA 
Input power, 4-20mA loop:  8 - 35 VDC, 22 mA
Operating temperature range:  -200C to 500C (-40F to 1220F)
Operating humidity range:  0 to 95% RH non-condensing
Response:  sensor T90  < 5 sec.
Sensor:  PID Lamp, 10.6 eV (Krypton)
Lamp duty cycle:  selectable 5 sec. to 5 min. (1 min. std.)
Sampling process:  diffusion
Output signal:  4 - 20 mA
Dimensions:  7.11x4.88x2,86 in (181x124x72.6 mm)
Weight:  2.9 lbs. (1.3 kg)
Display:  7 segment 4-digit LCD, 4 colors
Calibration:  four stage
Ingress protection: (TVOC) - IP65; (sensor) - IP54
Intrinsic safe approvals:  II 2 G Eex ia IIC T4, cert # Baseefa05ATEX0277